LED emergency drivers supply battery-backed power to compatible LED lighting when normal power fails. DC-output and AC/DC backup designs support different fixture configurations, with output voltage, emergency wattage, and wiring matched to the connected lighting.

Compare (0/5)

5 of 45 products

RAB Lighting - 5W Emergency Battery Backup Inverter, Type B Lamps Compatible | Bees Lighting
Quick Ship

RAB Lighting

5W Emergency Battery Backup Inverter, Type B Lamps Compatible

Regular price $72.00
Sale price Regular price $0.00
RAB Lighting - 10W Emergency Battery Backup Inverter, Type B Lamps Compatible | Bees Lighting
Quick Ship

RAB Lighting

10W Emergency Battery Backup Inverter, Type B Lamps Compatible

Regular price $81.00
Sale price Regular price $0.00
EiKO 5W red emergency battery backup unit with mounting brackets
NewQuick Ship

Eiko

EiKO 5W Emergency Battery Backup, Non-Dimming, Constant Power Bypass Tube Backup, 120-277V

Regular price $64.90
Sale price Regular price $0.00
LED Emergency Drivers, 10 Watts, 40-100V DC High Voltage Output - Bees Lighting
Quick Ship

SATCO|NUVO

10W LED Emergency Drivers, 40-100V DC Output

Regular price $139.30
Sale price Regular price $0.00
LED Emergency Ballast, 1300 Lumens, 120-277V Input, Type A Lamps, 90 Minutes - Bees Lighting
Quick Ship

Espen

LED Emergency Ballast, 1300 Lumens, Type A Lamps, 90 Minutes

Regular price $89.95
Sale price Regular price $0.00

An emergency LED driver (also known as a BBU or battery backup unit) is a critical safety component that converts your existing light fixtures into code-compliant emergency lighting. In many architectural or commercial spaces, installing separate "bug eye" emergency lights can ruin the aesthetic. An emergency lighting driver offers a discreet solution. When the main AC power fails, the driver automatically detects the outage and switches the fixture to battery power, keeping the lights on for the required 90 minutes. This ensures safe egress without the need for additional wall-mounted hardware.

Types of Emergency Battery Backup Drivers

Different fixtures require different driver form factors. We stock solutions for every application:

  • Outdoor & Wall Pack: Specialized drivers for exterior fixtures like wall packs and canopy lights. These often feature a 2-piece split design (separating the battery from the control module) to fit inside tight die-cast housings while maintaining Wet Location ratings.
  • Linear & T8: Long, slim drivers designed to fit inside the ballast channel of strip lights and vapor tight fixtures.
  • Compact & Downlight: Small metal enclosures with flexible conduit, designed to sit on top of recessed cans or in tight plenums.
  • Panel & Troffer: Integrated boxes that mount to the back of 2x2 or 2x4 flat panels.
  • High Bay & Industrial: High-wattage, rugged drivers (often IP65 rated) capable of powering powerful UFO high bays in warehouses.

How Emergency Drivers Power Your Fixtures

Selecting the correct LED emergency battery pack depends on how the driver interacts with your fixture's electronics. There are two primary methods:

1. Powering the LED Module Directly (Low Voltage DC): Many emergency drivers work alongside the fixture's normal driver but operate independently during an outage. In an emergency, they bypass the normal driver and deliver power directly from the battery to the LED chips.

  • Output: Typically Low-Voltage DC (15-60VDC).
  • Compatibility: You must match the driver's output voltage range to the specific requirements of the LED array (the board itself).
  • Benefit: Highly efficient and common in integrated LED fixtures like linear strips.

2. Powering the Normal Fixture Driver (High Voltage AC/DC): Other emergency LED drivers are designed to power the fixture's existing AC driver, essentially acting like a mini-inverter.

  • Output: High-Voltage AC (often 120VAC or 277VAC) or High-Voltage DC (up to 500VDC).
  • Compatibility: This method uses the fixture’s own electronics to power the LEDs. It is ideal for fixtures where you cannot access the internal LED board or where the voltage requirements are non-standard.
  • Benefit: Simplifies installation for complex fixtures like screw-in lamps or sealed downlights.

Shop LED Emergency Battery Backup Units

Don't leave your safety to chance. At Bees Lighting, we carry a comprehensive selection of UL 924 listed emergency ballasts and LED drivers. Whether you are retrofitting a single office downlight or outfitting an entire warehouse with backup power, we have the compatible components. Browse our collection to find the right wattage and form factor for your project.

Frequently Asked Questions

How long must an emergency driver light a fixture?

According to UL 924 standards, all emergency drivers must keep the fixture illuminated for a minimum of 90 minutes.

Why do some outdoor emergency drivers use a two-piece design?

Outdoor fixtures like wall packs are compact and often get very hot. The 2-piece split design allows the installer to place the battery in a cooler or more accessible spot within the housing, separate from the control module, ensuring the battery lasts longer and fits into tight casting spaces.

How do I choose the right wattage for an emergency driver?

You don't need to match the fixture's full wattage; you only need enough light for safety. To calculate emergency lumens, multiply the Emergency Driver Wattage by the Fixture's Efficacy (Lumens per Watt).

Example: A 10W emergency driver x 100 lm/w fixture = 1,000 Lumens in emergency mode.

What is the difference between an emergency ballast and an LED driver?

Technically, "ballasts" are for fluorescent tubes and "drivers" are for LEDs. However, many people use the terms interchangeably. If you have LED fixtures, you need an Emergency LED Driver. If you have older fluorescent tubes, you need a Fluorescent Emergency Ballast.

What is a self-testing or self-diagnostic emergency driver?

A self-testing (or self-diagnostic) emergency driver is an advanced model that automatically performs the required monthly and annual tests. It uses an indicator light to signal its operational status, battery charge, or any faults, simplifying maintenance and compliance.

How do I check whether an LED emergency driver is compatible with my fixture?

Compare the emergency driver’s output voltage, supported load, and wiring arrangement with the fixture’s LED module and normal driver. Confirm that the manufacturer permits the combination and that the components fit within their specified mounting and temperature limits.

What is the difference between DC-output and AC/DC-output emergency drivers?

A low-voltage DC-output emergency driver bypasses the normal fixture driver during an outage and powers the LED module directly, so its output range must match the LED array. A high-voltage AC/DC-output model instead powers the fixture’s normal driver, which then operates the LEDs; compatibility must be checked against that driver’s supported input.

Can an emergency LED driver work with dimming controls?

Compatibility depends on the normal driver, dimming system, and emergency driver’s wiring requirements. Follow the specified connections so that normal dimming operates as intended without disabling the emergency power supply.

Where should the battery and test indicator be mounted?

Mount the battery and control components only in locations permitted by the manufacturer, allowing for temperature limits, clearances, and service access. Position the test switch and indicator where they can be reached and observed without exceeding the permitted lead lengths.

How do I confirm the fixture provides enough light in emergency mode?

Use the fixture’s emergency-output data and photometric distribution to evaluate illumination along the intended walking path. After installation and the specified charging period, test the fixture on battery power and confirm its output and operating duration.

Learn More About LED Emergency Drivers

What is Emergency Lighting?

What is Emergency Lighting?

Emergency lighting is a legal requirement in many countries to ensure the safety of occupants in public and commercial buildings. The regulations and standards for emergency lighting vary depending on the jurisdiction.

Read more
emergency lights codes

A Guide to Emergency Light Codes and Standards

From illumination levels and battery tests to the wiring codes of NFPA 70, learn the critical safety standards that every emergency light must meet.

Read more
Compliance with NFPA 101: Life-Safety Rules for Testing and Maintaining Emergency Exit Signs and Battery Backups

Compliance with NFPA 101: Life-Safety Rules for Testing and Maintaining Emergency Exit Signs and Battery Backups

Take the guesswork out of life-safety compliance. Learn the legal emergency lighting codes mandated under NFPA 101, master mandatory monthly and annual battery drainage testing protocols, and discover how to optimize commercial layouts by branch-linking remote accessory heads to a centralized battery enclosure.

Read more