Collection: Fluorescent Emergency Ballasts

Emergency lighting ballasts supply battery-backed power to compatible fluorescent lamps when normal power fails. They work with the fixture’s normal ballast, with lamp type, lamp count, and emergency light output matched to the installation.

Compare (0/5)

1 product

LED Emergency Ballast, 1300 Lumens, 120-277V Input, Type A Lamps, 90 Minutes - Bees Lighting
Quick Ship

Espen

LED Emergency Ballast, 1300 Lumens, Type A Lamps, 90 Minutes

Regular price $89.95
Sale price Regular price $0.00

A fluorescent emergency ballast is the critical component required to bring linear tube fixtures up to code by ensuring they stay lit during a blackout. While LED is the modern standard, many commercial buildings still rely on legacy fluorescent lighting. Unlike standard ballasts which simply regulate current, these units contain a high-temperature nickel-cadmium battery. When power is lost, the emergency ballast automatically switches one or two connected lamps to emergency mode, operating them at a reduced lumen output to conserve battery life for the mandated 90-minute runtime.

T8, T5 & T12 Battery Backup Compatibility

Selecting the right unit requires matching the specific lamp type in your facility. We stock universal and specific models for all common tube sizes:

  • T8 Emergency Ballast: The industry standard for 4-foot office lighting. These versatile units typically power one or two F32T8 lamps.
  • T12 Support: We still carry hard-to-find T12 emergency ballast replacements for older fixtures that have not yet been retrofitted.
  • T5 & T5HO: High-output fixtures used in warehouses require specific high-voltage ballasts to strike the arc in T5HO lamps.
  • Compact Fluorescent (CFL): Specialized ballasts designed for 4-pin CFL lamps often found in recessed commercial downlights.

For LED fixture backup, compare LED emergency drivers, matching the backup design to the LED module or fixture driver rather than assuming fluorescent ballast compatibility.

Emergency Lumen Output

Crucially, a fluorescent battery backup does not run the lamps at full brightness. To determine if you are meeting the 1.0 foot-candle safety requirement, you must check the Initial Lumen Output rating:

  • Low Profile (500-700 Lumens): Ideal for standard 8-foot ceilings in hallways and offices.
  • High Output (1400-3000 Lumens): Required for high ceilings (warehouses/gyms) where you need maximum visibility from a distance during evacuation.

Shop Reliable Fluorescent Backup

Don't let a dead battery compromise your building's safety rating. At Bees Lighting, we carry industry-leading fluorescent emergency ballasts from top brands like Bodine ballast and IOTA. Whether you are maintaining a school full of T8 troffers or a warehouse of T5 high bays, we have the direct-replacement hardware you need. Browse our catalog to find the correct lamp compatibility.

For other backup illumination and exit identification options, explore our full emergency lighting range.

Frequently Asked Questions

Can I use a fluorescent emergency ballast with LED tubes?

It depends. If you use "Type A" (Ballast Compatible) LED tubes, they might work, but you must check the tube manufacturer's compatibility sheet. If you use "Type B" (Ballast Bypass) LED tubes, you cannot use a fluorescent emergency ballast; you must install an Emergency LED Driver instead.

What happens if I connect two lamps instead of one?

Most emergency ballasts allow you to wire either one or two lamps. If you wire two, the total light output is usually split between them (resulting in two dimmer lights). If you wire one, you get one brighter light. The total "Emergency Lumens" remains roughly the same.

How do I know if my ballast is dead?

There is a "Charging Indicator Light" and test button installed on the fixture. If the indicator light is out, or if the tubes don't turn on when you press the test button, the battery inside the ballast is likely dead, and the entire unit needs replacement.

What is the difference between a standard ballast and an emergency ballast?

A standard AC ballast powers the lights during normal operation. The emergency ballast sits dormant until the power goes out. You need both inside the fixture for it to work correctly (unless you have a rare "emergency-only" fixture).

How long do these batteries last?

The internal NiCad batteries typically have a lifespan of 5 to 7 years, depending on the ambient temperature. After this period, they will no longer hold a 90-minute charge, and the unit must be replaced.

How do I choose a fluorescent emergency ballast for an existing fixture?

Match the emergency ballast’s supported lamp type, wattage, and lamp count to the fixture. Confirm compatibility with the normal ballast and use the manufacturer’s wiring diagram for the exact lamp configuration.

Will fluorescent lamps operate at full brightness during an outage?

Not necessarily. Use the emergency ballast’s published emergency lumen output for the specified lamps rather than their normal-operation brightness. Fixture placement and light distribution determine how that output reaches the walking surface.

Can an emergency ballast be installed outside the fixture?

Some models permit remote mounting, while others require installation within the fixture. Follow the manufacturer’s mounting instructions, maximum wiring distance, and enclosure requirements.

Can fluorescent emergency ballasts be used in cold or damp locations?

Only when the model is rated for the installation’s temperature and moisture conditions. Check the battery’s operating limits and the complete fixture arrangement before selecting a unit.

What should I check after replacing an emergency ballast?

Follow the manufacturer’s charging instructions before performing an emergency-operation test. Verify that the intended lamps illuminate, the indicator and test switch function correctly, and the installation delivers the required emergency illumination.

Learn More About Emergency Lighting Ballasts

What is Emergency Lighting?

What is Emergency Lighting?

Emergency lighting is a legal requirement in many countries to ensure the safety of occupants in public and commercial buildings. The regulations and standards for emergency lighting vary depending on the jurisdiction.

Read more
emergency lights codes

A Guide to Emergency Light Codes and Standards

From illumination levels and battery tests to the wiring codes of NFPA 70, learn the critical safety standards that every emergency light must meet.

Read more
Compliance with NFPA 101: Life-Safety Rules for Testing and Maintaining Emergency Exit Signs and Battery Backups

Compliance with NFPA 101: Life-Safety Rules for Testing and Maintaining Emergency Exit Signs and Battery Backups

Take the guesswork out of life-safety compliance. Learn the legal emergency lighting codes mandated under NFPA 101, master mandatory monthly and annual battery drainage testing protocols, and discover how to optimize commercial layouts by branch-linking remote accessory heads to a centralized battery enclosure.

Read more