Keystone LED Emergency Light, Dual Square Heads, White, NYC & Chicago Compliant, 400 Lumens, 90-Min Battery Backup, 120-277V, 4.5W (KT-EM-STNC1-WHWL-SU)
Keystone LED Emergency Light, Dual Square Heads, White, NYC & Chicago Compliant, 400 Lumens, 90-Min Battery Backup, 120-277V, 4.5W (KT-EM-STNC1-WHWL-SU)
Available in stock (100)
Choose your location
enter a US zip code
Couldn't load pickup availability
About this item
About this item
- NYC & Chicago Code Compliant: Meets New York City and Chicago building code requirements
- 400 Lumens Output: Dual square heads with 9 LEDs each provide 6500K emergency illumination
- 90-Min Battery Backup: UL924 listed, Nickel-Metal Hydride 900mAh battery meets NEC/IBC requirements
- 22-Gauge Steel Housing: Durable 12.00" x 5.00" x 2.48" white steel construction
- Energy Efficient: 4.5W consumption, 120-277V, RoHS compliant, Keystone quality with 5-year warranty
Shipping & Returns
Shipping & Returns
Shipping: Enjoy free standard shipping on most orders over $99. (Exclusions apply for oversized & commercial items). We ship to the contiguous 48 United States.
Returns: We offer a 60-day return window for most items. Products must be in their original, unused condition with all packaging. (Exclusions: Special orders, clearance, and custom items).
We process payments securely and do not store credit card information.
Description
Description
Keystone KT-EM-STNC1-WHWL-SU LED Emergency Light - NYC & Chicago Code Compliant
The Keystone KT-EM-STNC1-WHWL-SU is a Keystone Technologies LED emergency light designed for code-compliant emergency egress illumination meeting New York City and Chicago building codes. This code-compliant emergency lighting solution features dual adjustable square lamp heads with 9 LEDs per head delivering 400 lumens, 90-minute battery backup, and universal 120-277V voltage. The 22-gauge steel housing with white finish provides durability while the energy-efficient LED technology ensures reliable emergency illumination for commercial buildings, multi-family residential, and institutional facilities requiring UL924-listed emergency lighting with NYC and Chicago code compliance.
Keystone KT-EM-STNC1-WHWL-SU Features
- NYC & Chicago Code Compliant: Meets New York City and Chicago building code requirements for emergency lighting
- Dual Square Lamp Heads: Two adjustable square heads with 9 LEDs each rotate and pivot for optimal emergency light coverage
- 400 Lumens Output: Bright, energy-efficient 6500K white LED illumination provides adequate egress path visibility
- 90-Minute Battery Backup: Meets NEC and IBC emergency duration requirements with Nickel-Metal Hydride 900mAh battery
- 22-Gauge Steel Housing: Durable white steel housing (12.00" W x 5.00" H x 2.48" D) for long-lasting performance
- Universal Voltage: 120-277V AC operation for flexible installation in commercial applications
- Energy-Efficient LED: 4.5W input power with 6500K color temperature
- Surface Mounting: Easy installation with back mount configuration and universal J-box pattern
- UL924 Listed: Certified for emergency lighting applications and code compliance
Keystone KT-EM-STNC1-WHWL-SU Specifications
- Brand: Keystone Technologies
- Model Number: KT-EM-STNC1-WHWL-SU
- UPC: 843654165226
- Product Type: LED Emergency Light - NYC & Chicago Code Compliant
- Lamp Head Type: Square, 2 adjustable heads, 9 LEDs per head
- Light Output: 400 lumens total
- Housing: 22-gauge steel, white
- Dimensions: 12.00" W x 5.00" H x 2.48" D
- Weight: 4.2 lbs
- Battery: Nickel-Metal Hydride 900mAh
- Battery Backup Time: 90 minutes minimum
- Recharge Time: 24 hours
- Input Voltage: 120-277V AC, 50/60Hz
- Input Power: 4.5W
- Color Temperature: 6500K
- Mounting: Surface mount, back mount, universal J-box pattern
- Operating Temperature: 0°C/32°F to 40°C/104°F
- Certifications: cULus, UL924 Listed, NYC & Chicago code compliant, damp location rated, RoHS compliant
- Warranty: 5 Years
Keystone KT-EM-STNC1-WHWL-SU Applications
- New York City commercial buildings and high-rises
- Chicago commercial buildings and multi-family residential
- Educational and healthcare facilities in NYC and Chicago
- Hospitality and retail stores requiring code compliance
- Industrial facilities, stairwells, and exit pathways
Installation & Operation
Surface mounts with back mount configuration and universal J-box pattern. Connect to 120-277V AC power and adjust dual square lamp heads for optimal egress path coverage. Unit automatically charges battery. During power loss, battery backup activates for 90 minutes of emergency illumination. Integrated test switch and charge indicator for easy code compliance verification.
NYC & Chicago Code Compliance
The KT-EM-STNC1-WHWL-SU is specifically designed to meet New York City and Chicago building code requirements for emergency lighting. The dual square heads with 9 LEDs per head deliver 400 lumens of emergency illumination, ensuring adequate visibility along egress paths during power outages. The 22-gauge steel housing provides durability for commercial installations while maintaining code-compliant performance.
Why Choose Keystone Emergency Lights
Keystone Technologies delivers code-compliant emergency lighting solutions engineered for reliability and ease of installation. The KT-EM-STNC1-WHWL-SU combines energy-efficient LED design with 90-minute battery backup, NYC and Chicago code compliance, and dual adjustable square lamp heads. With cULus and UL924 listing, universal 120-277V voltage, and flexible mounting options, this emergency light delivers professional-grade performance for demanding code requirements. With Keystone's 5-year warranty and reputation for quality, the KT-EM-STNC1-WHWL-SU delivers long-term reliability and value.
Why Buy From Us: As an authorized Keystone dealer, we guarantee 100% genuine products with full manufacturer warranty, expert technical support, and fast shipping.
Specifications
Specifications
Dimensions
Documents
Style & Materials
Characteristics & Features
Electrical Information
Item Details
Warranty & Certifications
Frequently Asked Questions
Where are emergency lights required?
Where are emergency lights required?
Emergency lighting is required along the "path of egress." This includes hallways, stairwells, corridors, and any room with an occupancy load of more than 50 people. The goal is to ensure that anyone in the building can see clearly enough to walk to the nearest exit.
How often do I need to test them?
How often do I need to test them?
Fire codes (NFPA 101) require a monthly 30-second test and an annual 90-minute test. All our units come with a "push-to-test" button to make the monthly check easy.
What is a "bug eye" light?
What is a "bug eye" light?
"Bug eye" is a nickname for the standard emergency light fixture that has a rectangular box (the battery housing) and two round, adjustable lamp heads on top or on the sides, which resemble the eyes of a bug or frog. They are the most popular type of emergency egress lighting due to their low cost and high effectiveness.
Can I use these outdoors?
Can I use these outdoors?
Only if the specific model is rated for "Wet Locations" or "Outdoor Use." Standard thermoplastic bug eye lights are typically for indoor use (Damp Location) only. If you install an indoor unit outside, moisture will corrode the battery.
Do these lights stay on all the time?
Do these lights stay on all the time?
No. These are "non-maintained" fixtures, meaning they are normally off. They only turn on when they detect that the building's main power has been lost.